臺灣科技大學—地源冷暖房空調系統 Ground Source HVAC

■ 校園專利 / ▼ NTUST

本設施為一種利用與淺層地底近恆溫之土壤與流動水體進行熱交換之機械空調系統,使用於冷房時可以同步降低對都市熱島之影響與系統整體耗能。熱交換機制包含達礫石層之50m深水循環與12m深氣循環,目前已完成水循環地源熱泵空調系統之實驗與使用設定。研究成果可作為地底散熱性能與系統設計之參考,其應用可推廣至地質近似但地溫較低的其他地區。本研究整合建築設計、大地工程與機械工程等領域專長,並配合業界進行地下埋設管線之專利開發。

50-rn deep water circulation in the gravel stratum and a 12-rn deep air circulation where the ground ternperature is near constant. The performance of air-conditioning using water cooled ground source heat pump has been tested and tuned. System construction and underground environment monitoring can serve as references for system design and thermal exchanger in- stallation. The results can be used to identify the application potential in other regions with sirni- lar geological features. The project has coordinated cross-disciplinary research capability in building design, geotechnical engineering.

研究團隊

江維華/廖洪鈞/黃建勝/郭治平/陳家瑞

Weihwa Chiang/Hungjiun Liao/Jiansheng Huang/Chihping Kuo/Chia-jui Chen

 

相關技術已應用於台北捷運車站建築

Silmilar systems have been tested in a MRT site.